LC-100 HP 100 Analytical High Performance Liquid Chromatograph for Laboratory Use Liquid Chromatography Gradient System

暂无价格
收藏
  • 商品說明

Product descriptions from the supplier

      The DAD detector, ELSD detector, FLD fluorescence detector, and RID differential detector can be selected according to the detection requirements
       Disposition:
Gradient system, Pump *2 + UV detector *1+ Automatic sampler *1+ Column temperature chamber *1+ Column
Infusion Unit
Model
LC-100 HP 100 (Analytical)
Infusion mode
dual-piston reciprocating parallel
Max Working Pressure
42MPa
Flow Range
0.001mL/min~9.999 mL/min
Flow Precision
RSD<0.07%
Fluctuation
0.1MPa
Power Source
220V /110V
UV Detector
Model
LC-100 UV
Flow cell volume
8μL
Light Source
D2 lamp
Wavelength Range
190~680nm
Wavelength Accuracy
±1nm
Wavelength Precision
0.1nm以下
Noise
±0.25×10-5AU (Static) / ±1×10-5AU (dynamic, under specified requirements)
Drift
≤0.4×10-4AU/h (Static) / 2×10-4AU/h (dynamic, under specified requirements)
Minimum Detectable Concentration
5×10-9 g/mL
Power Source
220V/110V
Column Oven
Model
CO100
Temperature Control Range
5℃-80℃, above room temperature
Temperature setting error
±2℃
Temperature Precision
±0.1℃
Power Source
220V /110V
Whole Set Test
Qualitative Repeatability
RSD6 ≤0.1% (Naphthalene/Methanol Standard Sample)
Quantitative Repeatability
RSD6 ≤0.3% (Naphthalene/Methanol Standard Sample)
Chromatograph
Workstation
Model
WS100
Signal Transmission Form
Full digital signal
Operation Mode
Reflecting and monitoring the operation of instruments’ each unit (editing gradient program for changing wavelength scanning,
setting event procedure, spectrum scanning, spectrogram comparison, etc.)
Interface
Chinese language interface, English interface (optional)
Installation Method
Built-in, installed by disc
Parameter of Arcus 5 Autosampler
Model
Arcus 5 Autosampler
Basic tray
2ml*54 (Factory standard equipment)
Upgrade tray
10ml*15 4ml*35
Vials height
<52mm
Volume
of metering pump:200μL
Injection mode
Full loop injection
Partial loop fill injection
μL pickup injection
Injection Volume
Full loop injection 0.1~120μL
Partial loop fill injection0.1~100μL(Can be extended to 200μL)
μL pickup injection 0.1~100μL(Can be extended to 200μL)
Quantitative Repeatability
Full loop injection RSD6≤0.3%
Partial loop fill injection RSD6≤0.5%(injection volume≥5μL)
μL pickup injection RSD6≤1.0%(injection volume≥10μL)
Memory effect
≤0.005%(according to designated washing program)
Maximum Pressure
(10000psi) 40MPa
Automatic Protection Function
Bottle lack alarm, Sample needle fault alarm, Pipeline jammed alarm, Leakage alarm
Both sides of the tray can be placed in any standard. System can automatically identify the type of tray.
Voltage
115V~230V,50Hz~60Hz
Column oven
      The temperature control parts and the solvent tray are designed as integrated.       This creates more practical functions, nicer appearance, and more stable temperature control, the range of which is 5 to 80 at room temperature.       Good retention time reproducibility is also demonstrated.  Two columns can be placed simultaneously to perform series analysis.         The whole system is under digital reverse control and all operations can be done on computer.
Parameter
Temperature control principle
Air circulation heating
Temperature setting range
5℃~80℃(At room temperature)
Temperature stability
±0.1℃
Temperature accuracy
±2℃(At 35℃)
Column number
2
Voltage
115V~230V, 50Hz~60Hz


Copyright @ 2025 Hefei Guochuang Analytical Instrument Co., Ltd All rights reserved.


Tel:0551-64324137      E-mail:Gootrol@gootrol-inst.com  


URL:www.ashrafstudio.com


Address:Building A, Xinda Ginkgo Plaza, No. 88 Science Avenue, High tech Zone, Hefei City